The Cone Probe meets UL1278 Fig 10.1 standards, featuring a stainless - steel probe and nylon handle. Designed to test heating elements and components, it ensures protection against contact with people and flammable materials. Engineered to the standard’s specifications, it delivers reliable results for safety compliance evaluations.
The stirrer shall incorporate a biased-off switch that is recessed or guarded to prevent accidental operation. It conforms to the IEC60335-2-14 requirement.
Appliance is checked by applying a cylindrical rod whose diameter is 40mm and which has a hemispherical end to touch the switch with a force not exceed 5N.The appliance shall not operated.
This test plug conforms to IEC60065 Figure 8 standard requirement. It is used to test the antenna coaxial socket which is installed on the device and equipped with parts or components which isolate the hazardous live parts and accessible parts. Its structure should be able to withstand the expected mechanical stress that might encounter during the use process. It is made entirely of stainless steel. All parts are machined with precision.
Food waste probe 31 confirms to IEC61032 figure 14 standard. It is used for checking food waste disposal units of milling system of hazardous mechanical parts whether is touched or not.Rod: Ø25mm, 80mm long, interchangeable metal or Delrin probe. It conforms to the IEC61032 Test probe 31.The handle is made of nylon,tip is made of stainless steel.
The UL accessibility probe is also called UL articulated probe or jointed test finger probe. It conforms to many standard requirement of UL474 Fig 5.1, UL507 Fig 9.2(PA100A), UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2, UL1278Fig 8.3, UL1310 Fig 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig NAF.1.
HT-U16 Test Finger Probe is designed in strict accordance with UL507 Fig 8.2 (S2140A) standard. Its innovative nylon handle + stainless steel probe combination takes into account both operational comfort and detection accuracy, providing reliable protection for product safety.
It conforms to the standard of UL499 Fig 6.4 and UL982-2006 Fig 58.5(PA190). It is applicable for the electrical equipment. The handle is made of Nylon, and the tip is stainless steel.
HT-U09 Test Finger Probe is manufactured in strict accordance with the international standard UL507 Fig 8.2 (S2140A) and is suitable for safety testing of stationary fans and impellers and other moving parts of fans that are intended to be permanently electrically connected.