The Cone Probe meets UL1278 Fig 10.1 standards, featuring a stainless - steel probe and nylon handle. Designed to test heating elements and components, it ensures protection against contact with people and flammable materials. Engineered to the standard’s specifications, it delivers reliable results for safety compliance evaluations.
The stirrer shall incorporate a biased-off switch that is recessed or guarded to prevent accidental operation. It conforms to the IEC60335-2-14 requirement.
Appliance is checked by applying a cylindrical rod whose diameter is 40mm and which has a hemispherical end to touch the switch with a force not exceed 5N.The appliance shall not operated.
HT-U16 Test Finger Probe is designed in strict accordance with UL507 Fig 8.2 (S2140A) standard. Its innovative nylon handle + stainless steel probe combination takes into account both operational comfort and detection accuracy, providing reliable protection for product safety.
This probe conforms to the IEC60335-2-11 figure 104 and IEC60335-2-6-2002 figure 104 standard requirements. It is mainly used to measure the temperature rise on the front surface of the easily accessible parts of drum-type dryer, upright electric cooker, cooking bench and oven.
This pin is intended to verify the protection against access to hazardous live parts in class 0 equipment and class II equipment. It conforms to IEC61032 figure 9 Test probe13, IEC60950 figure 2B, IEC60335 and IEC60065 standard requirements.
Customizable: It can be used for enclosure protection test when open threaded hole of M6 at the end of the handle (connected with pull and push dynamometer).
This pin is intended to be used on appliances for verifying the inaccessibility of hazardous live parts or hazardous mechanical parts which are liable to be touched accidentally by a tool, for example a screwdriver or similar pointed object in normal use. It meets IEC61032 figure 8 test probe 12. Handle is made of nylon while the tip is made of hardened steel.Customizable: It can be used for enclosure protection test when open threaded hole of M6 at the end of the handle (connected with pull and push dynamometer).
The HT-U07 triangular probe strictly complies with the UL1278 Fig 10.3 standard and is specially designed for safety protection detection of heating elements and components. It protects flammable materials and personnel safety with precise and reliable performance.
The test thorn probe is intended to verify the protection against access to glowing heating elements. It complies with IEC61032 figure 16 Test probe 41, IEC60335 standard requirements.
The test hook complies with IEC60065. It is used to test whether the dangerous electric parts can be touched. The test hook is “hooked” into vents and seams in the enclosure & then pulled with a force (usually 20N). The hook has a hole at its long end, for use in conjunction with a PFI series Force Gauge. It is made entirely of stainless steel.
We know your desire for precision and reliability, so the HT-I28 Test Finger Probe was born. It is not just a tool, but also your trusted partner in the field of electrical safety. Whether it is the door interlock device detection of the microwave oven, or the anti-electric shock, shell protection and other tests, it can bring you a safe testing experience with accurate parameters and stable performance.
The test pin is used to do the scratch resistant test of the electrical solid insulation surface. It conforms to the standard requirement of IEC60335-1 clause 21.