The test hook complies with IEC60065. It is used to test whether the dangerous electric parts can be touched. The test hook is “hooked” into vents and seams in the enclosure & then pulled with a force (usually 20N). The hook has a hole at its long end, for use in conjunction with a PFI series Force Gauge. It is made entirely of stainless steel.
Item No. :
HT-I18Minimum Order Quantity (MOQ) :
1 setPayment Method :
L/C, T/TPrice :
NegotiatableProduct Origin :
ChinaSupply Ability :
100 sets / per monthLead Time :
7 daysConventional packaging :
Aluminum boxIEC60065 Figure 4 Test Finger Probe Stainless Steel Test hook With 90° angle
Standard:
IEC60065-1 ‘Audio, video and similar electronic apparatus - Safety requirements’ figure 4.
Application:
It is used to test the enclosure mechanical strength of audio,video and similar electronic apparatus.
Test sample:
Audio,video and similar electronic apparatus.
Feature:
It is used to test whether the dangerous electric parts can be touched. The test hook is “hooked” into vents and seams in the enclosure & then pulled with a force 20±2 N last for 10s. The hook has a hole at its long end, for use in conjunction with a PFI series Force Gauge. It is made entirely of stainless steel.
Technical parameters:
Parameters/Model |
Test hook HT-I18 |
1 |
180±0.05 |
2 |
8±0.15 |
3 |
5±0.05 |
4 |
1±0.15 |
5 |
90°
|
Hot Tags :