Specifically designed for water purifier diaphragm pumps and washing machine drain pumps, this fully automatic life aging tester simulates severe operating conditions (up to 80°C, 0-1.6MPa). It ensures your products meet stringent standards like Q/HR 0503009, optimizing your R&D and QA processes.
Item No. :
HCLPT-008Minimum Order Quantity (MOQ) :
1 SetPayment Method :
T/T,L/CPrice :
NegotiatableProduct Origin :
China/TürkiyeSupply Ability :
1 sets per 2 monthsLead Time :
60 daysConventional packaging :
PlywoodOptimize product reliability with our 20-Station Intelligent Pump Durability Test Equipment (HCLPT-008). Designed for source manufacturers, this system accurately predicts faults by simulating real-world operating conditions up to 80°C and 1.6MPa, ensuring your pumps meet rigorous international standards.
The HCLPT-008 provides versatile durability testing solutions across multiple sectors:
Equipped with dual pressure sensors (0-0.6MPa before pump, 0-1.6MPa after pump) with an accuracy of ±1% F.S., alongside an integrated DC power meter (0-60V / 0-5A) for comprehensive thermal and electrical monitoring.
Features an integrated upper supply and lower leak collection tank system, maximizing water efficiency during long-term durability assessments.
| Standard Name | Clause/Detail | Description |
|---|---|---|
| Q/HR 0503009 | Drain Pump Requirements | Specialized life aging tests for drain pumps. |
| IEC/EN 60335-2-11 | Cl. 20.102 (Drain Pumps) | Safety of household tumble dryers (Durability requirements). |
| IEC/EN 660335-2-35 | Cl. 20 (Motor Endurance) | Instantaneous water heaters circulation pump fatigue tests. |
| GB/T 4216.2 | Life Test Requirements | Centrifugal pumps long-term running durability assessment. |
| Parameter | Specification / Range |
|---|---|
| Test Stations | 20 Stations |
| Test Medium Temperature | Room Temp. - 80°C (Temperature Controlled) |
| Water Tank Material | SUS304 Stainless Steel (Upper Supply + Lower Leak Collection) |
| Pressure Sensors | Inlet: 0-0.6MPa | Outlet: 0-1.6MPa (Accuracy ±1% F.S.) |
| Power & Voltage | Input: 0-60V (Adjustable) | Main Supply: 220V, 3.5KW |
| Control System | PLC Data Acquisition Software + HMI |
| Equipment Dimensions | 1850 × 680 × 1720 mm |
A: Yes, the 20-station design allows for independent or simultaneous aging tests of multiple batches and different pump models, significantly increasing your testing throughput.
A: The system features a dual-tank SUS304 configuration. It heats the water up to 80°C and continuously recirculates it during the test, ensuring eco-friendly and energy-efficient operation.
A: Absolutely. The intelligent PLC system and custom software automatically detect faults, record performance data in real-time, and allow for flexible test parameter definitions suitable for strict R&D audits.